| System
W+ White |
| Literature |
download pdf |
| Application Notes System W+ |
download pdf |
| Application Notes Basecoat |
download pdf |
| Application Notes Top Seal |
download pdf |
| Type |
Water-Borne
Intumescent Clear Basecoat and Top seal |
| Properties |
Area of Use |
Internal |
| Specific
Gravity (SG) |
1.39 (basecoat) |
| Specific
Gravity (SG) |
0.85 (top seal) |
| Volume
Solids |
60% |
| Flash
Point |
NA |
| Colour |
White (basecoat) / Clear (top seal) |
| Technical |
Preparation |
Refer
to Application Notes |
| WFT (microns) |
Refer to Literature |
| DFT (microns) |
Refer to Literature |
| Drying Time |
Touch
dry 1 hour (basecoat) / 2 hours (top seal) |
| Over Coating |
6 hours (basecoat) / 24 hours (top seal) |
| Fire Performance |
Euroclass B-s1, d0 |
| Steel Section |
Timber
and wood derivatives |
| Certification |
EN 13823 and EN ISO 11925-2 |
| Top Seal
Requirement |
Over
Coating |
Top
seal should be applied as soon as basecoat is fully cured |
| Building Classification |
C1
buildings |
| General |
Application
Method |
Brush or airless
spray |
| Container Size |
5kg/25kg (basecoat) / 2.5kg/10kg (top seal) |