S605
Literature
Application Notes
Type Solvent-Based Intumescent basecoat
Properties Area of Use Internal or External
Specific Gravity (SG) 1.36
Volume Solids 68% +-2%
Flash Point 30°C
Colour Very pale green
Technical Preparation Onto clean dry compatible primer
WFT (microns) Brush: <375 Spray: <1100
DFT (microns) Brush: <255 Spray: <748
Drying Time 24 hours between coats at >100C
Over Coating Minimum 3 days at >100C before top coat. Heavy loadings may need longer
Fire Performance 30, 60, 90 and 120 minutes
Steel Section Universal and hollow steel sections
Certification BS476:Part 20/21:1987 ASFP Approved
Top Seal Requirement Over Coating Can be left without topseal for 12 months
Building Classification C3 buildings
General Application Method Airless spray, short pile roller or brush
Container Size 25kg drum